1. Home
  2. Brushless Motors
  3. NeuMotors 3000 Series BLDC Motors: 10,000 to 30,000 watt class

30xx SERIES BRUSHLESS MOTORS

Neumotors 3020 3030 10,000-30,000 watt class motors

30xx SERIES QUICK LOOK:

  • 78.5mm OD
  • Inrunner construction
  • 10,000W – 30,000W
  • 30,000+ max rpm
  • 4 poles / 12 slots
  • 12mm shaft

Neumotors 3000 series brushless motors are manufactured in a wide variety of lengths and winds to provide increasing power ratings at a number of voltages. Select the desired motor power range from the table below.

OPTIONS:

  • Finned case
  • splash resistant / dust resistant
  • US component sourcing and assembly available

May be mated with P42 or P62 gearboxes for very high power-to-weight drives.

30xx Neumotors BLDC motor

30XX LENGTHS & POWER RANGES

Length
Continuous
Watts*
Max
Watts*
Physical
Length
Weight
Price*
10,000
20,000
103mm
1,934g
$1098.00
15,000
30,000
128mm
2,900g
$1649.00

*  Volume discount available.

 3020: 10,000-20,000 watt class BLDC motors

Price: $1098.00 each.  Volume discount available.

Motor RPMs
per Volt
(KV)
Rm (Ohms) Io
@
10V
Torque
Constant
(mNm/A)
Torque
Constant
(inOz/A)
Max
Volts
Max
Amps
3020/4Y 165 0.041 1.50 57.99 8.212
3020/3Y 233 0.022 2.00 41.066 5.815
3020/2.5Y 292 0.015 2.40 32.769 4.64
3020/2Y 350 0.011 3.00 27.338 3.871
3020/1.5Y 535 0.005 4.00 17.885 2.533
3020/1Y 700 0.002 6.00 13.669 1.936

3030: 15,000-30,000 watt class BLDC motors

Price: $1649.00 each.  Volume discount available.

Motor RPMs
per Volt
(KV)
Rm (Ohms) Io
@
10V
Torque
Constant
(mNm/A)
Torque
Constant
(inOz/A)
Max
Volts
Max
Amps
3030/3Y 155 0.032 2.00 61.732 8.742
3030/2.5Y 194 0.023 2.40 49.322 6.985
3030/2Y 233 0.014 3.00 41.066 5.815
3030/1.5Y 356 0.008 4.00 26.878 3.806
3030/1Y 466 0.004 6.00 20.533 2.908



LEAD TIME

Neutronics assembles motors to order.  Most motors in this series are ready to ship from our San Diego office within 3-6 weeks.  Lead time varies with quantity, customizations, and supply chain considerations.  Rush orders may be available.

Please email us to confirm delivery estimates for your motor needs. info@neutronics.com

MOTOR KV:

The motor sizes and KVs listed above are the most common for this particular motor range. Custom sizes and  KV (RPMs per volt) are usually available.  Please contact us for more details if you don't immediately see the solution you are seeking in the tables above.

KV is the term used in the brushless motor workspace to specify the number of rotations per minute that a motor will turn for each volt applied to the motor/ESC with no load on the motor.

Neutronics specifications are +/- 5%.

For a more complete discussion of KV, please go to our KV FAQ page.  

POWER RATINGS (Watts):

  • Continuous rating is the power the motor can deliver while maintaining the external housing temperatures below 100C.
  • MAX power is achieved at max RPMs and voltage, not at a partial throttle or reduced voltage.
  • MAX power rating is the power the motor can deliver beginning with motor at a temp of 20C until it reaches it's limit temperature of 100C.
  • The ratings are therefore dependent on a number of variables including air flow, ambient air temperature, contact cooling etc. Each application will present different variables.  

MTBF RATINGS:

When used within the constraints described above, BLDC motors' primary "wear" item(s) are the bearings supporting the shaft. Bearing life is inversely affected by speed, temperature, and radial and axial loads.  While an MTBF figure can be generated, it would be rendered invalid by excursions beyond prescribed temperatures or load limits - such as prop strikes, or side loads.  MTBF must be determined on a case by case basis, and even then, it would be subject to numerous exceptions.

MAX VOLTAGE

Limited by kv (RPMs per volt) times the applied voltage.  Max voltage must be kept below the voltage which will spin the motor over max rpm for the motor series.

MAX AMPERAGE

See power ratings above.

COMPONENT SPECIFICATIONS

  • Winding temperature:  -- 180C
  • Magnet grade: - 180C UH grade
  • Bearings:  Japanese SPB bearings

CONTROLLER SETTINGS: TIMING

  • APD controllers automatically adjust timing for optimum efficiency
  • Recommend low timing for controllers that require configuration

Pole Count vs. Pole Pairs

  • Neumotors lists the number of poles in a motor rotor. Example: N S N S would be a four pole motor.
  • Some ESC manufacturers use the term "pole pairs" which refers to the number of N and S pairs.  Example: N S N S would be a 2 pole pair motor.   

Neumotors Naming Convention Details

NOTE: Innrunners use imperial dimensions (inches), outrunners use metric dimensions (mm).

Using the 1530/.75D (2640 KV) as our example:  1530/.75D (2640 KV) should be read as 15 | 30 | .75 | D which runs at 2,640 RPMS per volt.


1530/.75D (2640 KV)

The last part of the code - the Kv, is the voltage constant.* It represents the number of RPMs the motor will spin for each volt applied to the motor by the speed control.  A 1,000 KV motor should spin at 10,000 RPMs when 10 volts are applied to an unloaded motor (10 x 1,000 = 10,000).

The Kv of a particular motor size is determined by the number of turns of wire around the stator teeth.  The length of the motor and the type of wire termination inside the motor also determine the motor Kv.

*Kv in this context does not mean kilovolt.  We aren't working with kilovolts here!!


1530/.75D (2640 KV)

The first two digits are the motor's internal diameter in inches. 15 = 1.5" inches - so all 15 series are the same internal diameter.


1530/.75D (2640 KV)

The second two digits represent the motor's internal length, the stator stack, specifically. 30 is 3.0 inches - so a 1530 is 3 inches long inside and a 1539 is 3.9 inches long inside the case. Longer motors have more power capability and more weight.


1530/.75D (2640 KV)

The 3rd set of digits is the number of times the internal wires are wrapped around the stator teeth. 1530/.75D has .75 wraps of the wire inside the motor around the steel teeth of the stator.


1530/.75D (2640 KV)

The final letter refers to the internal connection of the 3 motor wires. D = Delta, the Greek letter for D that looks like a triangle. The other option is Y, and the Y wind looks like a letter Y on a wiring diagram.  A Delta motor will spin 1.8 times the Kv of a Y motor with the same number of turns.  Change the turns in a Y motor and it will spin just as fast as a Delta with nearly identical performance.

NOTE: This system applies to the NEUMOTORS INRUNNERS.  OUTRUNNERS are the same format, but they are in metric units (MM).