- Outrunner construction
- 12,000 max rpm
- 22 poles / 24 slots
- 8mm shaft
Neumotors 65xx series brushless motors are manufactured in a wide variety of lengths and winds to provide increasing power ratings at a number of voltages. Select the desired motor Kv (RPMs per volt) and power range from the table below.
Custom Kv (RPMs per volt) are available.
6515 BLDC motors
Motor | RPMs per Volt (KV) | Rm (Ohms) | Io @ 10V | Torque Constant (mNm/A) | Torque Constant (inOz/A) | Max Volts | Max Amps |
6515 | 506 | 0.0115 | 2.4 | 23 | 217 |
6521 BLDC motors
Motor | RPMs per Volt (KV) | Rm (Ohms) | Io @ 10V | Torque Constant (mNm/A) | Torque Constant (inOz/A) | Max Volts | Max Amps |
6521 | 362 | 0.0126 | 1.9 | 33 | 181 |
6530 BLDC motors
Motor | RPMs per Volt (KV) | Rm (Ohms) | Io @ 10V | Torque Constant (mNm/A) | Torque Constant (inOz/A) | Max Volts | Max Amps |
6530 | 253 | 0.0160 | 1.7 | 47 | 148 |
6542 BLDC motors
Motor | RPMs per Volt (KV) | Rm (Ohms) | Io @ 10V | Torque Constant (mNm/A) | Torque Constant (inOz/A) | Max Volts | Max Amps |
6542 | 181 | 0.0207 | 1.4 | 66 | 121 |
6560 BLDC motors
Motor | RPMs per Volt (KV) | Rm (Ohms) | Io @ 10V | Torque Constant (mNm/A) | Torque Constant (inOz/A) | Max Volts | Max Amps |
6560 | 127 | 0.0277 | 1.3 | 52.864 | 7.486 | 66 | 211 |
POWER RATINGS (Watts):
- Continuous rating is the power the motor can deliver while maintaining the external housing temperatures below 100C.
- MAX power rating is the power the motor can deliver beginning with motor at a temp of 20C until it reaches it’s limit temperature of 100C.
- The ratings are therefore dependent on a number of variables including air flow, ambient air temperature, contact cooling etc.
MAX VOLTAGE
Limited by kv (RPMs per volt) times the applied voltage. Max voltage must be kept below the voltage which will spin the motor over max rpm for the motor series.
MAX AMPERAGE
See power ratings above.
MTBF RATINGS:
When used within the constraints described above, BLDC motors’ primary “wear” item(s) are the bearings supporting the shaft. Bearing life is inversely affected by speed, temperature, and radial and axial loads. While an MTBF figure can be generated, it would be rendered invalid by excursions beyond prescribed temperatures or load limits – such as prop strikes, or side loads. MTBF must be determined on a case by case basis, and even then, it would be subject to numerous exceptions.
COMPONENT SPECIFICATIONS
- Winding temperature: — 180C
- Magnet grade: – 180C UH grade
- Bearings: Japanese SPB bearings