APD 80F3x ESC
$89.00
SPECIFICATIONS:
Peak Power Rating (kW) | 4 | Weight (No cables) (g) | 10 | |
Continuous Current (A) | 80 | Dimensions (mm) | 51 x 23 x 14 | |
Continuous Rating Duration (s) | 180 | Input Signal PWM Frequency | 1000 | |
Burst Current (A) | 140 | Input PWM Frequency Pulse Width (ms) | 300 to 1200 | |
Burst Rating Duration (s) | 5 | Motor De-sync Protection | NO | |
Max Voltage (V) | 35 | Auto Motor PWM-Freq | YES | |
Max No. of LiPo Cells | 8 | Regenerative Braking | YES | |
Min Voltage (V) | 9 | Max Regen Current (A) | 10 | |
Min No. of LiPo Cells | 4 | Max Regen Voltage | 110% Power on Voltage | |
Max ERPM | 750,000 | Auto Timing Advance | YES | |
Input Resolution | 10 bit | Stall Protection | YES | |
Resistance (Ohms) | .0013 | Configurator Tool | NO | |
Max Operating Temperature (⁰C) (50% current limit start point) | 115 | Data Logging (Black Box) | NO | |
Recommended Airflow to achieve max power ratings (m/s) | 10 | Bi-Directional Control | NO | |
Decoupling Capacitor | 1 x 330uF 50V | Micro USB Firmware Flashing | NO |
Products marked "Not Suggested for New Designs" are scheduled to be superceded by Hargrave Technologies. These products will remain in production indefinitely for customers with existing applications.
Peak power ratings defined at 100% throttle, where bus current = phase current. Requires proper sizing of motor to load.
(*) Continuous amps defined as amperage sustainable for 180 seconds with adequate cooling to keep ESC at or below 115C
(**) Burst amps defined as amperage sustainable without damage to controller for a period of 5 (five) seconds. Burst should not be encountered again until ESC has returned to normal temperature
(***) Weight refers solely to the circuit board and enclosure, if any. Weight measured without any wires or connectors.
Specifications subject to change without notice.